AM0-A is a high-performance controller built on a modular integrated architecture, supporting both AC induction and permanent-magnet synchronous motors. It delivers a maximum output current of 250A.
Feature
Application
Full Featured
1. Diverse communication options, supporting both UART and CAN.
2. Extensive peripheral interfaces:
a) 7 low-power output channels (up to 1.5 A each),
b) 2 throttle inputs
c) 15 digital inputs
d) 1 channel of 0–10 V analog output.
3. Automatic parameter identification for AC induction motors and zero-point calibration for IPMSM/BLDC encoders.
4. Three-loop control of position, speed, and torque.
5. Proprietary robust speed control under varying loads and low-speed smooth-start technology for an exceptional vehicle control experience.
6. Configuration and debugging via handheld programmer, PC software, or mobile app, delivering unmatched flexibility.
Robust Safety and Reliability
1. overvoltage, over-temperature, and short-circuit protection to ensure reliable operation under harsh conditions.
2. Low-power output ports with both short-circuit and open-circuit protection.
3. Robust, sealed housing and connectors meeting IP65 environmental sealing standard for use in demanding environments.
Specification
Item | Parameter | |||||
P/N | AM0-A-2201 | AM0-A-2251 | ||||
Nominal Input Voltage (V) | 24 | 24 | ||||
1 Min output Current Rating (Arms) | 200 | 250 | ||||
60 Min output Current Rating (Arms) | 60 | 75 | ||||
Sensor | Incremental and absolute encoders | |||||
Communication | Serial / CAN | |||||
Working Temperature | -40℃~55℃ | |||||
Storage Temperature | -40℃~85℃ | |||||
Insulation | 10MΩ Insulation resistance, 0.05mA leakage @ DC 500V In/Out on casing. | |||||
IP Rating | IP65 | |||||
Vibration Standard | GB/T 2423 | |||||
Control Method | Vector control (field-oriented control, FOC) | |||||
Heatsink Requirement | Installed in well-ventilated or an air cooling system is required | |||||
Application | AC induction / synchronous motors | |||||
Encoder type | Incremental AB / ABI (IIF protocol) |
Note: 60 Min RMS Current Rating is measured under proper heat-sink assistance.